Paper |
Title |
Page |
MOPMB034 |
Design and Application of Double-slit Emittance Meter for C-ADS Proton Beams |
164 |
|
- L. Yu, Y.F. Sui, J.X. Zhao, D.C. Zhu
IHEP, Beijing, People's Republic of China
|
|
|
To reduce the beam loss in the high current linac, beam transverse emittance is a key value which has to be characterized. At Institute of High Energy Physics (IHEP) in Beijing the C-ADS project has started beam commissioning. A newly developed double-slit emittance meter (DEM) for pulsed proton beam from the (RFQ) has been installed in the beam line. In this paper principal of operation, instrumentation and programming of emittance meter are discussed. The emittance measurement has been carried out with the newly developed DEM at a beam energy of 3.2 MeV and a beam current of 10 mA. Typical rms emittance for x and y direction are measured to be 0.1303 and 0.1347 π mm mrad,which are well below the design standard of the RFQ.
|
|
Export • |
reference for this paper to
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
MOPOY027 |
Emittance Measurement with Wire Scanners at C-ADS Injector-I |
910 |
|
- H. Geng, C. Meng, Y.F. Sui, F. Yan, L. Yu, Y.L. Zhao
IHEP, Beijing, People's Republic of China
|
|
|
The transverse emittance at C-ADS injector-I has been measured by the wire scanners at the Medium Energy Beam Transport-I (MEBT1). We have studied the effect of different fitting methods for obtaining the beam sizes on the emittance result, the result will be presented in this paper. The validation study of the quad-scan method with the presence of space charge effect at 10 mA will also be shown, and finally the quad-scan results will be compared with the multi-wire results.
|
|
Export • |
reference for this paper to
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
MOPOY031 |
Emittance Measurement with Double-Slit Method in CADS Injector-I |
922 |
|
- C. Meng, H. Geng, Z. Xue, F. Yan, L. Yu, Y.L. Zhao
IHEP, Beijing, People's Republic of China
|
|
|
The C-ADS accelerator is a CW (Continuous-Wave) proton linac with 1.5 GeV in beam energy, 10 mA in beam current, and 15 MW in beam power. CADS Injector-I accelerator is a 10-mA 10-MeV CW proton linac, which uses a 3.2-MeV normal conducting 4-Vane RFQ and superconducting single-spoke cavities for accelerating. The 5MeV test stand of CADS accelerator Injector I is composed of an ion source, a LEBT, a 325MHz RFQ, a MEBT, a cryogenic module (CM1) of seven SC spoke cavities (β=0.12) , seven SC solenoids, seven cold BPMs and a beam dump. Emittance measurement is very important for the understanding of beam behavior and matching to the next accelerating section. Detailed emittance measurement with double-slit method after CM1 are presented in this paper.
|
|
Export • |
reference for this paper to
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|