Paper |
Title |
Page |
MOPMR032 |
Measurement of Beam Size with a SR Interferometer in TPS |
313 |
|
- M.L. Chen, H.C. Ho, K.H. Hsu, D.-G. Huang, C.K. Kuan, W.Y. Lai, C.J. Lin, S.Y. Perng, C.W. Tsai, T.C. Tseng, H.S. Wang
NSRRC, Hsinchu, Taiwan
|
|
|
Taiwan Photon Source (TPS) has operated since 2015. An optical diagnostic beamline is constructed in section 40 of TPS for the diagnosis of the properties of the electron beam. One instrument at this beamline is a synchrotron radiation interferometer (SRI), which is operated to monitor the beam size. In this paper, we present the beamline structure and recent results of measurement with the SR interferometer.
|
|
Export • |
reference for this paper to
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPMR058 |
Survey and Alignment for Taiwan Photon Source Storage Ring |
2405 |
|
- W.Y. Lai, M.L. Chen, H.C. Ho, K.H. Hsu, D.-G. Huang, C.K. Kuan, C.J. Lin, S.Y. Perng, C.W. Tsai, T.C. Tseng, H.S. Wang
NSRRC, Hsinchu, Taiwan
|
|
|
The Taiwan Photon Source (TPS) is a 3 Gev synchrotron light source located in Hsinchu, Taiwan. The commissioning of the beam began on December 2014, and the phase 1 stored current of 100mA was achieved on March 2015. Then the installation and alignment of insertion device were complete during the shutdown from April to July, and also the scheduled maintenance of survey control points was complete in the meantime. This report presents survey alignment results and experience of the TPS .
|
|
Export • |
reference for this paper to
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|