Author: Kamiya, J.
Paper Title Page
WEOBB03 A Non-destructive Profile Monitor Using a Gas Sheet 2102
 
  • N. Ogiwara, Y. Hikichi, J. Kamiya, M. Kinsho, Y. Namekawa
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken, Japan
  • M. Fukuda, K. Hatanaka, T. Shima
    RCNP, Osaka, Japan
 
  We are developing a dense gas-sheet target to realize a non-destructive and fast-response beam profile monitor for 3 GeV rapid cycling synchrotron (RCS) in the J-PARC. This time, to demonstrate the function of the gas sheet for measuring the 2 dimensional profiles of the accelerated beams, the following experiments were carried out: 1) The gas sheet with a thickness of 1.5 mm and the density of 2×10-4 Pa was generated by the combination of the deep slit and the thin slit. Here, the gas sheet was produced by the deep slit, and the shape of the sheet was improved by the thin slit. 2) For the electron beam of 30 keV with a diameter greater than 0.35 mm, the position and the two-dimensional profiles were well measured using the gas sheet. 3) Then the profiles of the 400 MeV proton beam with a current of 1×10-6 A was well measured, too.  
slides icon Slides WEOBB03 [4.718 MB]  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMR046 Thermal Analysis of the Injection Beam Dump at J-PARC RCS 2380
 
  • J. Kamiya, M. Kinsho, P.K. Saha, K. Yamamoto
    JAEA/J-PARC, Tokai-mura, Japan
 
  In the J-PARC accelerator facility, 400 MeV H ions are injected from linac to rapid cycling synchrotron (RCS). A thin graphite foil with the thickness of about 300 ug/cm2 is located at the injection point to strip two electrons from H ion and convert it to proton. The charge stripping efficiency is usually more than 99.7 %. In other words, less than 0.3 % H ions are not accurately exchanged to protons. Most of those remaining H ions or H0 atoms (stripped only one electron from H ion) are eventually converted to protons by second and third graphite foils and transported to the beam dump. This beam dump consists of an iron block with the size of 0.3×0.3×0.4 m3 for beam stop and the iron block with the size of 3×3×2.5 m3 and concrete with the size of 6×6×6 m3 around the iron block for the radiation shielding. The radiation shielding was designed to endure the 4 kW proton beam to the beam dump. In this presentation, we show the thermal analysis of the beam dump and compare it to the real operation.  
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)