Paper |
Title |
Page |
MOPMR017 |
Design and Simulations of the Cavity BPM Readout Electronics for the ELI-NP Gamma Beam System |
264 |
|
- M. Cargnelutti, B.B. Baricevic
I-Tech, Solkan, Slovenia
- A. Mostacci
University of Rome La Sapienza, Rome, Italy
- S. Pioli, M. Serio, A. Stella, A. Variola
INFN/LNF, Frascati (Roma), Italy
|
|
|
The Extreme Light Infrastructure - Nuclear Physics (ELI-NP) facility will provide a high intensity laser and a very intense gamma beam which will be used in a broad range of experiments. The gamma beam is obtained through incoherent Compton back-scattering of a laser light off a high brightness electron beam provided by a 700MeV warm LINAC. Electrons are accelerated in trains with up to 32 bunches, each one separated by 16ns. In the laser-electron interaction region, every bunch needs to be monitored with a resolution below 1μm RMS. To achieve this performance, a low-Q cavity beam position monitor will be used in combination with a dedicated data acquisition system able to perform bunch-by-bunch beam position measurements with sub-μm resolution. Using fast A/D converters and specific digital filtering, the readout system proposes an alternative measurement concept. The requirements of the system, its design and the results from the simulations will be presented.
|
|