TY - CONF AU - Trad, G. AU - Bravin, E. AU - Goldblatt, A. AU - Mazzoni, S. AU - Mitsuhashi, T.M. AU - Roncarolo, F. ED - Schaa, Volker RW ED - Petit-Jean-Genaz, Christine ED - Ko, In Soo ED - Kim, Dong Eon ED - Kim, Kyung Sook TI - Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC J2 - Proc. of IPAC2016, Busan, Korea, May 8-13, 2016 C1 - Busan, Korea T2 - International Particle Accelerator Conference T3 - 7 LA - english AB - During the LHC long shut down in 2014, the transverse beam size diagnostics based on synchrotron radiation was upgraded in order to cope with the increase of the LHC beam energy to 6.5 TeV. The wavelength used for imaging was shifted to near ultra-violet to reduce the contribution of diffraction to the system resolution, while in parallel, a new diagnostic system based on double slit interferometry was installed to measure the beam size by studying the spatial coherence of the emitted synchrotron radiation. This method has never been implemented before in a proton machine. A Hartmann mask was also installed to identify possible wavefront distortions that could affect the system accuracy. This paper will focus on the comparison of visible and the near ultra-violet imaging and on the first experience with interferometry. PB - JACoW CP - Geneva, Switzerland SP - 306 EP - 309 KW - radiation KW - extraction KW - synchrotron KW - synchrotron-radiation KW - diagnostics DA - 2016/06 PY - 2016 SN - 978-3-95450-147-2 DO - 10.18429/JACoW-IPAC2016-MOPMR030 UR - http://jacow.org/ipac2016/papers/mopmr030.pdf ER -