A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Stephan, F.

Paper Title Page
WEPPP07 Phase Space Tomography Diagnostics at the PITZ Facility 194
 
  • G. Asova, S. Khodyachykh, M. Krasilnikov, F. Stephan
    DESY Zeuthen, Zeuthen
  • P. Castro, F. Loehl
    DESY, Hamburg
 
  Funding: This work has partly been supported by the European Community, contract 011935 (EUROFEL)

A high phase-space density of the electron beam is obligatory for the successful operation of a Self Amplified Spontaneous Emission - Free Elector Laser (SASE-FEL). Detailed knowledge of the phase-space density distribution is thus very important for characterizing the performance of the used electron sources. The Photo Injector Test Facility at DESY in Zeuthen (PITZ) is built to develop, operate and optimize electron sources for FELs. Currently a tomography module for PITZ is under design as part of the ongoing upgrade of the facility. This contribution studies the performance of the tomography module. Errors in the beam size measurements and their contribution to the calculated emittance will be studied using simulated data. As a practical application the Maximum Entropy Algorithm (MENT) will be used to reconstruct the data generated by an ASTRA simulation.