MOPHA066 |
Electronics for LCLS-II Beam Containment System Shut-off |
366 |
MOPHA065 |
|
|
- R.A. Kadyrov, D.G. Brown, E.P. Chin, C.I. Clarke, M. Petree, E. Rodriguez, F. Tao
SLAC, Menlo Park, California, USA
|
|
|
LCLS-II is a new FEL which is under construction at SLAC National Accelerator Laboratory. Its superconducting electron linac is able to produce up to 1.2 MW of beam power. Beam Containment System (BCS) is employed to limit the beam power and prevent excessive radiation in case of electron beam loss or FEL breach. Fast and slow shut-off paths are designed for devices with different response requirements. The system is required to shut-off the beam within 200 µs for some of the fast sensors. Fast path is based on custom electronic designs, and slow path leverages industrial safety-rated PLC hardware. The system spans for 4 km of LCLS-II and combines inputs from about 150 sensors of different complexity. Architecture is based on multiple levels starting with summing sensor inputs locally and to converting them into permits for the shut-off devices. Each level is implemented redundantly. Automated test and manual tests at all levels are implemented in the system. System architecture, electronics design and cable plant challenges are presented below.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-ICALEPCS2019-MOPHA066
|
|
About • |
paper received ※ 27 September 2019 paper accepted ※ 10 October 2019 issue date ※ 30 August 2020 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THCPR03 |
A Safety Rated FPGA Framework for Fast Safety Systems |
1626 |
|
- F. Tao, B.M. Bennett, D.G. Brown, J. Jones, M.W. Stettler
SLAC, Menlo Park, California, USA
|
|
|
In this paper, we will introduce a generic safety-rated FPGA design template. FMEDA analysis, hardware reliability modeling, firmware development, verification and validation will be described in details to demonstrate the IEC 61508 compliant development process. In this dual redundant design, each chain consists a FPGA chip from different manufacturers to minimize the potential common cause failures. Cross checks between FPGAs and end-to-end self-checks are performed to increase the diagnostic coverage and improve the reliability. Based on this safety FPGA template, an Average Current Monitor (ACM) system is developed at SLAC with the addition of a safety PLC for diagnostics and a HMI for user interface. The overall system is deployed as part of Beam Containment System (BCS) to limit the beam current with the target Safety Integrity Level (SIL) 2.
|
|