Author: Weilbach, T.
Paper Title Page
TUP20 Correction for Systematic Errors in Transverse Phase Space Measurements at PITZ 273
 
  • C.J. Richard, Z. Aboulbanine, G.D. Adhikari, N. Aftab, P. Boonpornprasert, G.Z. Georgiev, M. Groß, A. Hoffmann, M. Krasilnikov, X.-K. Li, A. Lueangaramwong, R. Niemczyk, H.J. Qian, F. Stephan, G. Vashchenko, T. Weilbach
    DESY Zeuthen, Zeuthen, Germany
 
  Funding: This work was supported by the European XFEL research and development program
The Photo Injector Test Facility at DESY in Zeuthen (PITZ) characterizes and optimizes electron sources for use at FLASH and European XFEL. AT PITZ, the transverse phase space is measured using a single slit scan and scintillator screen method. With the trend in photoinjectors towards lower current and emittance, these measurements become increasingly influenced by systematic errors including camera resolution and scintillator response due to smaller spot sizes. This study investigates the effects and corrections of the systematic errors for phase space measurements at PITZ.
 
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-TUP20  
About • Received ※ 07 September 2022 — Revised ※ 10 September 2022 — Accepted ※ 13 September 2022 — Issue date ※ 01 November 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUP21 Scintillator Nonproportionality Studies at PITZ 277
 
  • A.I. Novokshonov, G. Kube, S. Strokov
    DESY, Hamburg, Germany
  • Z. Aboulbanine, G.D. Adhikari, N. Aftab, P. Boonpornprasert, G.Z. Georgiev, J. Good, M. Groß, C. Koschitzki, M. Krasilnikov, X. Li, O. Lishilin, A. Lueangaramwong, D. Melkumyan, F. Mueller, A. Oppelt, H.J. Qian, F. Stephan, G. Vashchenko, T. Weilbach
    DESY Zeuthen, Zeuthen, Germany
 
  A standard technique to measure beam profiles in linear accelerators are screen monitors using scintillating screens. This technique is used e.g. at the European XFEL in order to overcome coherence effects in case of OTR usage [*]. During the XFEL commissioning it was found out that screens based on LYSO:Ce as scintillating material revealed a nonproportional light output [**]. Reason for it is the high particle beam density. As consequence it was decided to exchange LYSO:Ce by GAGG:Ce scintillators because the excitation carriers can rapidly transfer their energy to excited states of gadolinium, and a rapid migration of this energy among the Gd sub-lattice is expected. Driven by the observations at XFEL a series of measurements was started to investigate the properties of various scintillator materials (LYSO:Ce, YAP:Ce, YAG:Ce, LuAG:Ce and GAGG:Ce). The last measurement campaign was carried out at PITZ which allows to operate at higher beam charge and lower electron energy compared to the XFEL. The present work summarizes the results of these measurements.
* S.Wesch and B.Schmidt, in Proc. DIPAC’11, Hamburg, WEOA01, pp. 539-543.
** G.Kube, A.Novokshonov, S.Liu, M.Scholz, in Proc. FEL’19, Hamburg, WEB01, pp. 301-306.
 
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-TUP21  
About • Received ※ 11 September 2022 — Revised ※ 13 September 2022 — Accepted ※ 11 October 2022 — Issue date ※ 15 October 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)