Author: Thomasset, M.
Paper Title Page
TUP19 Visible Range Polarized Imaging for High Resolution Transverse Beam Size Measurement at SOLEIL 269
 
  • M. Labat, A. Bence, A. Berlioux, B. Capitanio, G. Cauchon, J. Da Silva, N. Hubert, D. Pédeau, M. Thomasset
    SOLEIL, Gif-sur-Yvette, France
 
  SOLEIL storage ring is presently equipped with three diagnostics beamlines: two in the X-ray range (pinhole cameras) and one in the visible range. The visible range beamline relies on a slotted copper mirror extracting the synchrotron radiation from one of the ring dipoles. The extracted radiation is then transported down to a dedicated hutch in the experimental hall. Up to now, this radiation was split into three branches for rough monitoring of the beam transverse stability, bunch length measurements and filling pattern measurements. In the framework of SOLEIL’s upgrade, we now aim at developing a new branch for high resolution beam size measurement using polarized imaging. This work presents the various modifications recently achieved on the beamline to reach this target, including a replacement of the extraction mirror, and preliminary results towards transverse beam size measurement.  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-TUP19  
About • Received ※ 09 September 2022 — Revised ※ 10 September 2022 — Accepted ※ 13 September 2022 — Issue date ※ 25 September 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)