Author: Lantschner, M.
Paper Title Page
WEP20 Emittance Diagnostics at PETRA IV 430
 
  • M. Marongiu, G. Kube, M. Lantschner, A.I. Novokshonov, K. Wittenburg
    DESY, Hamburg, Germany
 
  The PETRA IV project will be a Diffraction Limited Light Source designed to be the successor of PETRA III, the 6 GeV 3rd generation hard X-Ray synchrotron light source at DESY in Hamburg. It will operate at a beam energy of 6 GeV with a design emittance of 20/4 pm rad. For a precise emittance online control, two dedicated diagnostics beamlines will be built up to image the beam profile with synchrotron radiation in the X-Ray region. With two beamlines, it will be possible to extract both the transverse beam emittances and the beam energy spread. Both beamlines will be equipped with two interchangeable X-Ray optical systems: a pinhole camera system to achieve high dynamic range and a Fresnel Diffractometry system for high resolution measurements in the range 1-18 um. This paper describes the planned setup and deals with the possible limitations.  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-WEP20  
About • Received ※ 05 September 2022 — Revised ※ 10 September 2022 — Accepted ※ 11 September 2022 — Issue date ※ 26 September 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)