Author: Krasilnikov, M.
Paper Title Page
MOP28 Improvements in Longitudinal Phase Space Tomography at PITZ 105
 
  • N. Aftab, Z. Aboulbanine, P. Boonpornprasert, G.Z. Georgiev, J. Good, M. Groß, A. Hoffmann, M. Krasilnikov, X.-K. Li, A. Lueangaramwong, R. Niemczyk, A. Oppelt, H.J. Qian, C.J. Richard, F. Stephan, G. Vashchenko
    DESY Zeuthen, Zeuthen, Germany
  • W. Hillert
    University of Hamburg, Institut für Experimentalphysik, Hamburg, Germany
  • A.J. Reader
    KCL, London, United Kingdom
 
  Methodical studies to improve the longitudinal phase space (LPS) tomography of space-charge dominated electron beams were carried out at the Photo Injector Test facility at DESY in Zeuthen (PITZ). An analytical model was developed to quantify mean momentum, RMS energy spread, bunch length and phase advance. Phase advance analysis determined the booster phase scan range and step size to be used for obtaining momentum projections. A slit was introduced before the booster to truncate the beam in transverse plane to strongly reduce the space charge effects. The signal resolution of this truncated beam was improved by careful beta function control at the reference screen of the momentum measurements. The reconstruction algorithm was changed from Algebraic Reconstruction Technique (ART) to Image Space Reconstruction Algorithm (ISRA) owing to its assurance of non-negative solutions. In addition, the initial physically justified assumption of LPS, based on low-energy section measurements, was established to clear out noise-like artefacts. This paper will highlight the improvements made in the LPS tomography and compare the simulated and experimental results.  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-MOP28  
About • Received ※ 06 September 2022 — Revised ※ 12 September 2022 — Accepted ※ 13 September 2022 — Issue date ※ 15 October 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUP20 Correction for Systematic Errors in Transverse Phase Space Measurements at PITZ 273
 
  • C.J. Richard, Z. Aboulbanine, G.D. Adhikari, N. Aftab, P. Boonpornprasert, G.Z. Georgiev, M. Groß, A. Hoffmann, M. Krasilnikov, X.-K. Li, A. Lueangaramwong, R. Niemczyk, H.J. Qian, F. Stephan, G. Vashchenko, T. Weilbach
    DESY Zeuthen, Zeuthen, Germany
 
  Funding: This work was supported by the European XFEL research and development program
The Photo Injector Test Facility at DESY in Zeuthen (PITZ) characterizes and optimizes electron sources for use at FLASH and European XFEL. AT PITZ, the transverse phase space is measured using a single slit scan and scintillator screen method. With the trend in photoinjectors towards lower current and emittance, these measurements become increasingly influenced by systematic errors including camera resolution and scintillator response due to smaller spot sizes. This study investigates the effects and corrections of the systematic errors for phase space measurements at PITZ.
 
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-TUP20  
About • Received ※ 07 September 2022 — Revised ※ 10 September 2022 — Accepted ※ 13 September 2022 — Issue date ※ 01 November 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUP21 Scintillator Nonproportionality Studies at PITZ 277
 
  • A.I. Novokshonov, G. Kube, S. Strokov
    DESY, Hamburg, Germany
  • Z. Aboulbanine, G.D. Adhikari, N. Aftab, P. Boonpornprasert, G.Z. Georgiev, J. Good, M. Groß, C. Koschitzki, M. Krasilnikov, X. Li, O. Lishilin, A. Lueangaramwong, D. Melkumyan, F. Mueller, A. Oppelt, H.J. Qian, F. Stephan, G. Vashchenko, T. Weilbach
    DESY Zeuthen, Zeuthen, Germany
 
  A standard technique to measure beam profiles in linear accelerators are screen monitors using scintillating screens. This technique is used e.g. at the European XFEL in order to overcome coherence effects in case of OTR usage [*]. During the XFEL commissioning it was found out that screens based on LYSO:Ce as scintillating material revealed a nonproportional light output [**]. Reason for it is the high particle beam density. As consequence it was decided to exchange LYSO:Ce by GAGG:Ce scintillators because the excitation carriers can rapidly transfer their energy to excited states of gadolinium, and a rapid migration of this energy among the Gd sub-lattice is expected. Driven by the observations at XFEL a series of measurements was started to investigate the properties of various scintillator materials (LYSO:Ce, YAP:Ce, YAG:Ce, LuAG:Ce and GAGG:Ce). The last measurement campaign was carried out at PITZ which allows to operate at higher beam charge and lower electron energy compared to the XFEL. The present work summarizes the results of these measurements.
* S.Wesch and B.Schmidt, in Proc. DIPAC’11, Hamburg, WEOA01, pp. 539-543.
** G.Kube, A.Novokshonov, S.Liu, M.Scholz, in Proc. FEL’19, Hamburg, WEB01, pp. 301-306.
 
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-TUP21  
About • Received ※ 11 September 2022 — Revised ※ 13 September 2022 — Accepted ※ 11 October 2022 — Issue date ※ 15 October 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)