Author: Goldblatt, A.
Paper Title Page
TU3C3 LINAC4 Laser Profile and Emittance Meter Commissioning 357
 
  • A. Goldblatt, O.Ø. Andreassen, T. Hofmann, F. Roncarolo, J. Tagg
    CERN, Meyrin, Switzerland
  • G.E. Boorman, A. Bosco, S.M. Gibson
    Royal Holloway, University of London, Surrey, United Kingdom
 
  The LINAC4 is now equipped with two laser profile and emittance meters, basically non destructive and not limited by beam power density. A pulsed laser is transported through fibres and focused into the 160 MeV H beam. Its interaction with the H ions detaches electrons that are collected by an electron-multiplier, while the resultingH0 particles, after being separated from the main H beam by a dipole magnet, are recorded by a diamond strip detector, few meters away from the interaction point. The emittance and profile are reconstructed from the laser step by step scan of the beam. After several years of feasibility tests and prototyping, this paper will present all details about the final HW and SW implementation and the 2022 experimental results.  
video icon
 
  please see instructions how to view/control embeded videos  
slides icon Slides TU3C3 [1.035 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-TU3C3  
About • Received ※ 09 September 2022 — Revised ※ 10 September 2022 — Accepted ※ 11 September 2022 — Issue date ※ 23 September 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP23 Assessing the Performance of the New Beam Wire Scanners for the CERN LHC Injectors 443
 
  • S. Di Carlo, W. Andreazza, D. Belohrad, J. Emery, J.C. Esteban Felipe, A. Goldblatt, D. Gudkov, A. Guerrero, S. Jackson, G.O. Lacarrere, M. Martin Nieto, A.T. Rinaldi, F. Roncarolo, C. Schillinger, R. Veness
    CERN, Meyrin, Switzerland
 
  The ability of reliably measuring the transverse beam profile in its injectors is essential for the operation of the LHC. This report aims to assess the reliability, stability, and reproducibility of the new generation of beam wire scanners developed at CERN in the framework of the LHC Injectors Upgrade (LIU). The study includes data from the over 60000 scans performed in 2021 and 2022, with a special focus on reproducibility, investigation of optimal operational settings to ensure a large dynamic range, and evaluation of absolute accuracy through comparison with other instruments present in the injectors.  
poster icon Poster WEP23 [1.590 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2022-WEP23  
About • Received ※ 06 September 2022 — Revised ※ 10 September 2022 — Accepted ※ 11 September 2022 — Issue date ※ 10 December 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)