A New Luminosity Monitor for the LHC Run 3 |
163 |
|
- S. Mazzoni, W. Andreazza, E. Balci, D. Belohrad, E. Bravin, N.S. Chritin, J.C. Esteban Felipe, T. Lefèvre, M. Martin Nieto, M. Palm
CERN, Meyrin, Switzerland
|
|
|
The Beam Rate of Neutrals (BRAN) is a monitor that provides a relative luminosity measurement for the four LHC experiments. BRANs are used during operations as a tool to find and optimise collision and to cross-check experiments luminosity monitors. While each LHC experiments is equipped with BRANs, in this contribution we will focus on the new monitors installed for ATLAS and CMS that will replace the current ageing gas chambers during LHC run 3. These will also serve as as prototypes for the future High Luminosity LHC monitors that will need to sustain an even higher collision rate. A description of the BRAN as well as the first results obtained during the LHC Run 3 start-up will be presented.
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-IBIC2022-MOP45
|
|
About • |
Received ※ 06 September 2022 — Revised ※ 09 September 2022 — Accepted ※ 14 September 2022 — Issue date ※ 23 November 2022 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEP23 |
Assessing the Performance of the New Beam Wire Scanners for the CERN LHC Injectors |
443 |
|
- S. Di Carlo, W. Andreazza, D. Belohrad, J. Emery, J.C. Esteban Felipe, A. Goldblatt, D. Gudkov, A. Guerrero, S. Jackson, G.O. Lacarrere, M. Martin Nieto, A.T. Rinaldi, F. Roncarolo, C. Schillinger, R. Veness
CERN, Meyrin, Switzerland
|
|
|
The ability of reliably measuring the transverse beam profile in its injectors is essential for the operation of the LHC. This report aims to assess the reliability, stability, and reproducibility of the new generation of beam wire scanners developed at CERN in the framework of the LHC Injectors Upgrade (LIU). The study includes data from the over 60000 scans performed in 2021 and 2022, with a special focus on reproducibility, investigation of optimal operational settings to ensure a large dynamic range, and evaluation of absolute accuracy through comparison with other instruments present in the injectors.
|
|
|
Poster WEP23 [1.590 MB]
|
|