Author: Desmarchelier, G.
Paper Title Page
WEP13
Status of the uTCA Digitizer BPM Design for SARAF Phase II  
 
  • P. Gil, J. Fernández
    7S, Peligros (Granada), Spain
  • G. Desmarchelier, R.D. Duperrier
    CEA-DRF-IRFU, France
  • G. Ferrand, N. Pichoff, C. Simon
    CEA-IRFU, Gif-sur-Yvette, France
 
  One of the crucial monitoring systems of any particle accelerator is the Beam Position Monitor (BPM). The purpose of a BPM is to provide information on the position, phase and current of the beam along the accelerator line. CEA Saclay must provide all beam diagnostics for SARAF-LINAC PHASE II in particular BPM. Based on the technical specifications of the CEA, Orolia-Spain is in charge of the design, development, manufacture and testing of the electronic system. A preliminary version of this system has been already tested at Orolia’s and CEA installations and the first results are going to be shown. The architecture, design and development as well as the performance of the BPM system will be presented in this paper. The benefits of the proposed architecture and the first results obtained under different conditions will be detailed  
poster icon Poster WEP13 [0.972 MB]  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)