Paper | Title | Page | |||
---|---|---|---|---|---|
TUOB01 | Studies of Beam Loss Monitors at the China Spallation Neutron Source | 180 | |||
|
|||||
Funding: National Natural Science Foundation of China (Grants No. 11575219, No. 11705215, and No. 11805220). Beam loss detection is essential for the machine protection and the fine tuning of the accelerator to reduce the induced radioactivity. The beam loss monitors (BLM) at the China Spallation Neutron Source (CSNS) are mainly divided into the following types: the coaxial cylindrical ionization chamber (IC) filled with Ar/N2 gas mixture, Xe, BF3 gas, and the scintillator with photomul-tipliers, among which the Ar/N2 IC is the main type. In the low-energy section of the linac (beam energy <20 MeV), the BF3 BLMs enclosed by a high-density poly-ethylene (HDPE) moderator are utilized to detect the beam losses. The Monte Carlo program FLUKA is employed to perform the relevant simulations. This paper presents the summary of the beamloss detection for the CSNS BLM system. Experimental studies and Monte Carlo simulations for beam loss monitors Tao Yang, et al. Phys. Rev. Accel. Beams 24, 032804 (2021) |
|||||
![]() |
|
||||
![]() |
Slides TUOB01 [11.778 MB] | ||||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2021-TUOB01 | ||||
About • | paper received ※ 03 September 2021 paper accepted ※ 27 September 2021 issue date ※ 09 October 2021 | ||||
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | ||||