Author: Ye, Q.
Paper Title Page
TUPWC08 The Cold Beam Position Monitors for the C-ADS Injector I Proton Linac 298
 
  • Y.F. Sui, J.S. Cao, H.Z. Ma, Q. Ye, L. Yu, J.H. Yue
    IHEP, People's Republic of China
 
  Funding: Work supported by China ADS Project (XDA03020000) and the National Natural Science Foundation of China (NO. 11205172, NO. 11475204)
The injector I of China Accelerator Driven Subcritical system (C-ADS), which is composed of an ECR ion source, a low energy beam transport line (LEBT), a radio frequency quadrupole accelerator (RFQ), a medium energy beam transport line (MEBT) and cryomodules with SRF cavities to boost the beam energy up to 10 MeV. The injector linac is equipped with beam diagnostics. Cold beam position monitor(BPM) is one of instrumentations of the injector. This paper describes the design and fabrication of the cold BPM pick-ups, and also the application of the BPM in commissioning of SRF cavities. Discussion of the promotion and other aspect will also be presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2017-TUPWC08  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)