JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for TU2AB3: Single-Shot Longitudinal Beam Profile and Terahertz Diagnostics at MHz - Towards GHz-Rates with High-Throughput Electronics

TY - CONF
AU - Caselle, M.
AU - BORGHI,, G.
AU - Balzer, B.M.
AU - Boscardin, M.
AU - Brosi, M.
AU - Bründermann, E.
AU - Funkner, S.
AU - Kehrer, B.
AU - Müller, A.-S.
AU - Nasse, M.J.
AU - Niehues, G.
AU - Patil, M.M.
AU - Ronchin, S.
AU - Rota, L.
AU - Schuh, M.
AU - Schönfeldt, P.
AU - Steinmann, J.L.
AU - Weber, M.
AU - Yan, M.
ED - Liu, Zhengzheng
ED - Lidia, Steven
ED - McCausey, Amy
ED - Schaa, Volker RW
TI - Single-Shot Longitudinal Beam Profile and Terahertz Diagnostics at MHz - Towards GHz-Rates with High-Throughput Electronics
J2 - Proc. of IBIC2017, Grand Rapids, MI, USA, 20-24 August 2017
C1 - Grand Rapids, MI, USA
T2 - International Beam Instrumentation Conference
T3 - 6
LA - english
AB - Accelerators with high bunch-repetition rates mandate high-throughput detector electronics to diagnose each individual bunch. KALYPSO with a 256-pixel detector line-array integrated in an fs laser-based electro-optical set-up allows longitudinal bunch profiling with sub-ps resolution as demonstrated at the storage ring ANKA for single-bunch mode operation at 2.7 MHz and also at the Eu-XFEL with a 4.5-MHz micro-bunch train. Improvements will enhance fs-time accuracy, reduce noise, and increase frame-rate. A custom front-end with an application-specific integrated circuit (ASIC) has been developed to operate with 10-MHz frame-rates at low noise. Several linear arrays with up to 1024 pixel and smaller pixel pitch were submitted for production. The development of a low-gain avalanche diode (LGAD) sensor will further improve the time resolution. Detector data is transmitted in the DAQ framework to external GPU-based clusters and processed in real-time at 7 Gbytes/s with a few μs latency. For beam dynamics studies we also develop KAPTURE capable to analyze terahertz detector pulses at GHz-repetition rates. These developments open new windows in beam diagnostics of modern accelerators.
PB - JACoW
CP - Geneva, Switzerland
SP - 136
EP - 140
KW - ion
KW - detector
KW - diagnostics
KW - radiation
KW - experiment
DA - 2018/03
PY - 2018
SN - 978-3-95450-192-2
DO - 10.18429/JACoW-IBIC2017-TU2AB3
UR - http://jacow.org/ibic2017/papers/tu2ab3.pdf
ER -