Author: Priebe, G.
Paper Title Page
MOBL02 First Experience with the Standard Diagnostics at the European XFEL Injector 14
 
  • D. Lipka, A. Affeldt, A. Awwad, N. Baboi, B. Barret, B. Beutner, F. Brinker, W. Decking, A. Delfs, M. Drewitsch, O. Frank, C. Gerth, V. Gharibyan, O. Hensler, M. Hoeptner, M. Holz, K.K. Knaack, F. Krivan, I. Krouptchenkov, J. Kruse, G. Kube, B. Lemcke, T. Lensch, J. Liebing, T. Limberg, B. Lorbeer, J. Lund-Nielsen, S.M. Meykopff, B. Michalek, J. Neugebauer, Re. Neumann, Ru. Neumann, D. Nölle, M. Pelzer, G. Petrosyan, Z. Pisarov, P. Pototzki, G. Priebe, K.R. Rehlich, D. Renner, V. Rybnikov, G. Schlesselmann, F. Schmidt-Föhre, M. Scholz, L. Shi, P.A. Smirnov, H. Sokolinski, C. Stechmann, M. Steckel, R. Susen, H. Tiessen, S. Vilcins, T. Wamsat, N. Wentowski, M. Werner, Ch. Wiebers, J. Wilgen, K. Wittenburg, R. Zahn, A. Ziegler
    DESY, Hamburg, Germany
  • R. Baldinger, R. Ditter, B. Keil, W. Koprek, R. Kramert, G. Marinkovic, M. Roggli, M. Stadler, D.M. Treyer
    PSI, Villigen PSI, Switzerland
  • A. Ignatenko
    DESY Zeuthen, Zeuthen, Germany
  • A. Kaukher
    XFEL. EU, Hamburg, Germany
  • O. Napoly, C. Simon
    CEA/DSM/IRFU, France
 
  The injector of the European XFEL is in operation since December 2015. It includes, beside the gun and the accelerating section, containing 1.3 and a 3.9 GHz accelerating module, a variety of standard diagnostics systems specially designed for this facility. With very few exceptions, all types of diagnostics systems are installed in the injector. Therefore the operation of the injector is served to validate and prove the diagnostics characteristics for the complete European XFEL. Most of the standard diagnostics has been available for the start of beam operation and showed the evidence of first beam along the beam line. In the following months the diagnostics has been optimized and used for improvements of beam quality. First operational experiences and results from the standard beam diagnostics in the injector of the European XFEL will be reported in this contribution.  
slides icon Slides MOBL02 [5.844 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOBL02  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPG76 Status of the Two-Dimensional Synchrotron Radiation Interferometer at PETRA III 829
 
  • A.I. Novokshonov, A. Potylitsyn
    TPU, Tomsk, Russia
  • G. Kube, M. Pelzer, G. Priebe
    DESY, Hamburg, Germany
 
  Synchrotron radiation based emittance diagnostics at modern 3rd generation light sources is mainly based on beam profile imaging in the X-ray region in order to overcome the resolution limit imposed by diffraction. A possibility to circumvent this limitation is to probe the spatial coherence with a double-slit interferometer in the optical spectral region [*]. The light source PETRA III at DESY is using this type of interferometer since several years in order to resolve vertical emittances of about 10 pm.rad. The device is set up behind a 30m long optical beamline, connecting the accelerator tunnel and the optical hutch. In order to increase the measurement stability, a much shorter optical beamline with reduced number of optical elements was recently commissioned. At the end of the beamline, a two-dimensional interferometer was installed which allows to deduce transverse emittances in both planes simultaneously. This contribution summarizes the status of beamline and interferometer commissioning together with model calculations in order to investigate systematically the measurement accuracy.
*T. Mitsuhashi, "Twelve Years of SR Monitor Development", 2004 Beam Instrumentation Workshop, 2014, pp. 5-11.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WEPG76  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)