Author: Martinez, D.
Paper Title Page
WEPG31 Upgrades to the LANSCE Isotope Production Facilities Beam Diagnostics 690
 
  • H.A. Watkins, D. Baros, D. Martinez, L. Rybarcyk, J.D. Sedillo, R.A. Valicenti
    LANL, Los Alamos, New Mexico, USA
 
  Funding: Work supported by the U.S. Department of Energy. Contract No. DE-AC52-06NA25396
The Los Alamos Neutron Science Center (LANSCE) is currently upgrading the beam diagnostics capability for the Isotope Production Facility (IPF) as part of an Accelerator Improvement Project (AIP). Improvements to measurements of: beam profile, beam energy, beam current and collimator charge are under development. Upgrades include high density harps, emittance slits, wire-scanners, multi-segment adjustable collimator, data acquisition electronics and motion control electronics. These devices will be installed and commissioned for the 2017 run cycle. Details of the hardware design and system development are presented.
 
poster icon Poster WEPG31 [3.875 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WEPG31  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)