Author: Malyutin, D.
Paper Title Page
MOPG53 Electron Beam Probe Diagnostic for BESSY II Storage Ring 179
 
  • D. Malyutin, A.N. Matveenko
    HZB, Berlin, Germany
 
  A low energy electron beam can be used to characterize the high energy ultra-relativistic bunches. This technique allows one to obtain the bunch transverse profiles as well as the bunch length within a non-destructive single shot measurement. In this paper the bunch length measurement technique based on the interaction of the low energy electron beam with an ultra-relativistic bunch is described. Results of numerical simulations of measurements related to BESSY II are presented. A possible setup of such diagnostic system for BESSY II and in future for BESSY VSR is proposed.  
poster icon Poster MOPG53 [0.868 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOPG53  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)