Paper | Title | Page |
---|---|---|
WEPG69 | Profile Measurement by the Ionization Profile Monitor with 0.2T Magnet System in J-PARC MR | 811 |
|
||
A nondestructive Ionization Profile Monitor (IPM) is widely used to measure transversal profile. At J-PARC Main Ring (MR), three IPM systems have been used not only to measure emittances but also to correct injection miss matchings. To measure injection 3GeV beam profiles, the high external E field of +50kV/130mm at the maximum is used to guide ionized positive ions to a position sensitive detector; transversal kick force originating from space charge E field of circulating beam is a main error source which deteriorates profile. The strong B field is also used to compensate the kick force. To measure 30GeV bunched beam at the flat top on the fast extraction mode in good resolution, the strong B field of about 0.2T is needed. One set of magnet system, which consists of a C-type and two H-type magnets, were developed and installed in one IPM system. The IPM chamber was inserted between the 2 poles of the C-type magnet. To make the line integral of B field along the beam axis zero, the H-type magnets have the opposite field polarity to that of the C-type magnet and were installed on both sides of the C-type magnet. Details of the magnet system and its first trials will be presented. | ||
DOI • | reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WEPG69 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WECL03 | Measurement of the Beam Response to Quadrupole Kick by Using Stripline Pickup Monitor at J-PARC Main Ring | 604 |
|
||
Funding: Work supported by MEXT KAKENHI, GA 25105002, Grant-in-Aid for Scientific Research on Innovative Areas titled "Unification and Development of the Neutrino Science Frontier" In high intensity proton synchrotrons, linear and nonlinear betatron resonances cause beam loss. When the betatron tune spreads over a resonance line, the oscillation amplitude will get larger, causing a large beam loss. Our study aims for a direct measurement of the betatron tune spread by using a quadrupole kicker and a 4-electrode monitor. The monochromatic rf signal is inputted to the kicker and we induce an oscillation by kicking the beam. The amplitude of the quadrupole oscillation will depend on the number of particles having a certain tune. In the beam test at J-PARC MR, the dipole kicker was used as a quadrupole kicker by exciting the two facing electrodes in-phase. We measured the response to the kick at several frequencies. We observed that the amplitude depends on the kicker frequency and the number of particles per bunch. This demonstrates that the quadrupole oscillation can be induced by a kicker and the possibility of measuring the number of a particular tune particle from the response. We will present the result of the beam test and our prospect and the comparison between the experimental result and a numerical calculation. |
||
![]() |
Slides WECL03 [2.054 MB] | |
DOI • | reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WECL03 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |