Paper | Title | Page |
---|---|---|
MOBL02 | First Experience with the Standard Diagnostics at the European XFEL Injector | 14 |
|
||
The injector of the European XFEL is in operation since December 2015. It includes, beside the gun and the accelerating section, containing 1.3 and a 3.9 GHz accelerating module, a variety of standard diagnostics systems specially designed for this facility. With very few exceptions, all types of diagnostics systems are installed in the injector. Therefore the operation of the injector is served to validate and prove the diagnostics characteristics for the complete European XFEL. Most of the standard diagnostics has been available for the start of beam operation and showed the evidence of first beam along the beam line. In the following months the diagnostics has been optimized and used for improvements of beam quality. First operational experiences and results from the standard beam diagnostics in the injector of the European XFEL will be reported in this contribution. | ||
![]() |
Slides MOBL02 [5.844 MB] | |
DOI • | reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOBL02 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPG76 | Performance Studies of Industrial CCD Cameras Based on Signal-To-Noise and Photon Transfer Measurements | 540 |
|
||
Taking advantage of the rapid development and the huge market for commercial available optical sensors, in the past years optical measuring techniques took on greater significance. Nowadays, area scan CCD or CMOS sensors are widely used for beam profile diagnostics. They provide the full two-dimensional information about the particle beam distribution, allowing in principle to investigate shot-to-shot profile fluctuations at moderate repetition rates. In order to study the performance and to characterize these cameras, photon transfer is a widely applied popular and valuable testing methodology. In this contribution, studies based on signal-to-noise and photon transfer measurements are presented for CCD cameras which are in use for beam profile diagnostics at different DESY accelerators. | ||
DOI • | reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-TUPG76 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPG76 | Status of the Two-Dimensional Synchrotron Radiation Interferometer at PETRA III | 829 |
|
||
Synchrotron radiation based emittance diagnostics at modern 3rd generation light sources is mainly based on beam profile imaging in the X-ray region in order to overcome the resolution limit imposed by diffraction. A possibility to circumvent this limitation is to probe the spatial coherence with a double-slit interferometer in the optical spectral region [*]. The light source PETRA III at DESY is using this type of interferometer since several years in order to resolve vertical emittances of about 10 pm.rad. The device is set up behind a 30m long optical beamline, connecting the accelerator tunnel and the optical hutch. In order to increase the measurement stability, a much shorter optical beamline with reduced number of optical elements was recently commissioned. At the end of the beamline, a two-dimensional interferometer was installed which allows to deduce transverse emittances in both planes simultaneously. This contribution summarizes the status of beamline and interferometer commissioning together with model calculations in order to investigate systematically the measurement accuracy.
*T. Mitsuhashi, "Twelve Years of SR Monitor Development", 2004 Beam Instrumentation Workshop, 2014, pp. 5-11. |
||
DOI • | reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WEPG76 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |