MOPG11 Beam Commissioning of TPS Fast Orbit Feedback System 59
 
  • P.C. Chiu, Y.-S. Cheng, K.T. Hsu, K.H. Hu, C.H. Huang
    NSRRC, Hsinchu, Taiwan
 
  Submicron orbit stability for a low emittance synchrotron light source are essential. Besides locating and removing the existing perturbations, active orbit feedback is applied to improve the orbit stability below sub-micron range from DC to a few hundreds of Hertz. Efforts to investigate orbit stability and stabilization at TPS will be addressed in this report.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOPG11  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPG02 Commissioning of the Bunch-by-Bunch Transverse Feedback System for the TPS Storage Ring 612
 
  • Y.-S. Cheng, K.T. Hsu, K.H. Hu, C.H. Huang, C.Y. Liao
    NSRRC, Hsinchu, Taiwan
 
  TPS finish its Phase II commissioning in December of 2015 after installation of two superconducting RF cavities and ten sets of insertion devices in mid-2015. Storage beam current up to 520 mA was achieved. Intensive insertion devices commissioning were performed in March 2016 and delivery beam for beam-line commissioning and perform pilot experiments. One horizontal stripline kicker and two vertical stripline kickers were installed in May 2015. Bunch-by-bunch feedback system were commissioning in late 2015. Commercial available feedback processor was selected for the feedback system integration. Beam property and performance of the feedback system were measured. Results will summary in this report.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WEPG02  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPG06 Orbit Feedforward and Feedback Applications in the Taiwan Light Source 623
 
  • C.H. Kuo, P.C. Chiu, K.T. Hsu, K.H. Hu
    NSRRC, Hsinchu, Taiwan
 
  Taiwan Light Source (TLS) is a 1.5 GeV third-generation light source with circumference 120 meters. TLS is operated at 360 mA top-up injection mode. The storage ring is 6-fold symmetry with 6-meter straight sections for injection, RF cavity, and insertion devices. There are three undulators were installed in three straight sections to delivery VUV and soft X-ray for users. Beside there undulators, a conventional wiggler (W200 installed at straight sections to provide hard X-ray to serve user. Working parameters of hard X-ray sources are fixed without cause problem on operation. However, undulators should be changing its working parameters during user experiments performed. These undulator during its gap/phase changing will create orbit perturbation due to its field errors. Orbit feedback is main tool to keep orbit without change. However, some correctors setting of the orbit feedback system are easy to saturation due to large perturbation come from U90. To keep functionality of the orbit feedback system working in good condition, combines with orbit feedback and feed-forward is proposed and reported in this conference.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WEPG06  