TUBL04 Electro-Optical Methods for Multipurpose Diagnostics 290
 
  • R. Pompili, M.P. Anania, M. Bellaveglia, F.G. Bisesto, E. Chiadroni, A. Curcio, D. Di Giovenale, G. Di Pirro, M. Ferrario
    INFN/LNF, Frascati (Roma), Italy
  • A. Cianchi
    INFN-Roma II, Roma, Italy
  • A. Zigler
    The Hebrew University of Jerusalem, The Racah Institute of Physics, Jerusalem, Israel
 
  Electro-optic sampling (EOS) based temporal diagnostics allows to precisely measure the temporal profile of electron bunches with resolution of about 50 fs in a non-destructive and single-shot way. At SPARC_LAB we adopted the EOS in very different experimental fields. We measured for the first time the longitudinal profile of a train of multiple bunches at THz repetition rate, as the one required for resonant Plasma Wakefield Acceleration (PWFA) in a single-shot and non-intercepting way. By means of the EOS we demonstrated a new hybrid compression scheme that is able to provide ultra-short bunches (<90 fs) with ultra-low (<20 fs) timing-jitter relative to the EOS laser system. Furthermore, we recently developed an EOS system in order to provide temporal and energy measurements in a very noisy and harsh environment: electron beams ejected by the interaction of high-intensity (hundreds TW class) ultra-short (35fs) laser pulses with solid targets by means of the so-called Target Normal Sheath Acceleration (TNSA) method.  
slides icon Slides TUBL04 [2.183 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-TUBL04  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPG74 Spot Size Measurements in the ELI-NP Compton Gamma Source 532
 
  • F. Cioeta, E. Chiadroni, G. Di Pirro, G. Franzini, V. Shpakov, A. Stella, A. Variola
    INFN/LNF, Frascati (Roma), Italy
  • A. Cianchi
    INFN-Roma II, Roma, Italy
  • M. Marongiu
    INFN-Roma, Roma, Italy
  • A. Mostacci, L. Palumbo
    University of Rome La Sapienza, Rome, Italy
 
  A high brightness electron Linac is being built in the Compton Gamma Source at the ELI Nuclear Physics facility in Romania. To achieve the design luminosity, a train of 32, 16 ns spaced, bunches with a nominal charge of 250 pC will collide with the laser beam in the interaction point. Electron beam spot size is measured with an OTR (optical transition radiation) profile monitors. In order to measure the beam properties, the optical radiation detecting system must have the necessary accuracy and resolution. This paper deals with the studies of different optic configurations to achieve the magnification, resolution and accuracy desired considering design and technological constraints; we will compare several configurations of the optical detection line to justify the one chosen for the implementation in the Linac.  
poster icon Poster TUPG74 [44.049 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-TUPG74  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)