Author: Ausset, P.
Paper Title Page
MOPG79 Scintillating Screens Investigations with Proton Beams at 30 keV and 3 MeV 273
 
  • C. Simon, F. Harrault, F. Senée, O. Tuske
    CEA/DSM/IRFU, France
  • P. Ausset
    IPN, Orsay, France
  • E. Bordas, F. Leprêtre, Y. Serruys
    CEA, Gif-sur-Yvette, France
  • J. Fils
    GSI, Darmstadt, Germany
 
  Luminescent screens hit by accelerated charged particle beams are commonly used as beam diagnostics to produce a visible emitted light, which can be sensed by a camera. In order to investigate the characteristics of the luminescence response of several scintillators, the beam shape and the observation of the transverse position, experiments were done with different low intensity proton beams produced by two different test benches. This study is motivated by the need to identify scintilla-tor materials for the development of a 4-dimensional emittancemeter which will allow the characterization of the beams, in particular the emittance measurement (size, angular divergence). This paper describes the experimental setups and our investigations of the optical properties of various scintillating materials at two different proton beam energies respectively about 30 keV and 3 MeV. The light produced by these screens is characterized by yield, flux of the emitted light versus the beam intensity, time response, and long life-time and they are compared.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOPG79  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPG34 First Results from the IPHI Beam Instrumentation 413
 
  • P. Ausset, M. Ben Abdillah, S. Berthelot, C. Joly, J. Lesrel, J.-F. Yaniche
    IPN, Orsay, France
  • D. Bogard, B. Pottin, D. Uriot
    CEA/DSM/IRFU, France
 
  I.P.H.I. is a High Intensity Proton Injector (C.N.R.S/I.N.2P.3; C.E.A./Irfu and C.E.R.N. collaboration) located at Saclay and now on operation. An E.C.R. source produces a 100 keV, 100 mA C.W. proton beams which will be accelerated at 3 MeV by a 4 vanes R.F.Q. operating at 352.2 MHz. Finally, a High Energy Beam Transport Line (H.E.B.T.) delivers the beam to a beam stopper. The HEBT is equipped with appropriate beam diagnostics to carry beam current, centroid beam transverse position, transverse beam profiles, beam energy and energy spread measurements for the commissioning of I.P.H.I. These beam diagnostics operate under both pulsed and C.W. operation. However transverse beam profile measurements are acquired under low duty factor pulsed beam operation using a slow wire scanner. The beam instrumentation of the H.E.B.T. is reviewed and the first measurements at 3 MeV are described.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-TUPG34  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPG11 Operation of the Beam Position Monitor for the Spiral 2 Linac on the Test Bench of the RFQ 642
 
  • P. Ausset, M. Ben Abdillah, F. Fournier
    IPN, Orsay, France
  • S.K. Bharade, G. Joshi, P.D. Motiwala
    BARC, Trombay, Mumbai, India
  • R. Ferdinand, D.T. Touchard
    GANIL, Caen, France
 
  The SPIRAL2 project is based on a multi-beam superconducting LINAC designed to accelerate 5 mA deuteron beams up to 40 MeV, proton beams up to 33 MeV and 1 mA light and heavy ions (Q/A = 1/3) up to 14.5 MeV/A. The accurate tuning of the LINAC is essential for the operation of SPIRAL2 and requires measurement of the beam transverse position, the phase of the beam with respect to the radiofrequency voltage, the ellipticity of the beam and the beam energy with the help of Beam Position Monitor (BPM) system. The commissioning of the RFQ gave us the opportunity to install a BPM sensor, associated with its electronics, mounted on a test bench. The test bench is a D-plate fully equipped with a complete set of beam diagnostic equipment in order to characterize as completely as possible the beam delivered by the RFQ and to gain experience with the behavior of these diagnostics under beam operation. This paper addresses the first measurements carried with the BPM on the D-plate: intensity, phase, transverse position and ellipticity under 750 keV proton beam operation  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WEPG11  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)