RIS citation export for WEPG37: Nondestructive High-Accuracy Charge Measurement of the Pulses of a 27 MeV Electron Beam from a Linear Accelerator

TY - CONF
AU - Schüller, A.
AU - Illemann, J.
AU - Kapsch, R.-P.
AU - Makowski, C.
AU - Renner, F.
ED - Schaa, Volker RW
TI - Nondestructive High-Accuracy Charge Measurement of the Pulses of a 27 MeV Electron Beam from a Linear Accelerator
J2 - Proc. of IBIC2016, Barcelona, Spain, Sept. 13-18, 2016
C1 - Barcelona, Spain
T2 - International Beam Instrumentation Conference
T3 - 5
LA - english
AB - This work presents a description of measuring devices and procedures in order to enable the nondestructive (non-intercepting) absolute measurement of the charge of individual beam pulses (macro-pulses) from an electron linear accelerator with high accuracy, i.e. with a measurement uncertainty <0.1%. In particular, we demonstrate the readout and calibration of a Bergoz integrating current transformer which is frequently applied at many different types of accelerators as a beam intensity monitor. The current transformer signal is calibrated against a custom-made compact Faraday cup with a high degree of collection efficiency for electron beams in the energy range of 6 MeV to 50 MeV (99.2 % at 27 MeV), which is well known from measurements and Monte Carlo calculations.
PB - JACoW
CP - Geneva, Switzerland
SP - 709
EP - 712
KW - linac
KW - electron
KW - radiation
KW - vacuum
KW - monitoring
DA - 2017/02
PY - 2017
SN - 978-3-95450-177-9
DO - 10.18429/JACoW-IBIC2016-WEPG37
UR - http://jacow.org/ibic2016/papers/wepg37.pdf
ER -