Author: Deng, B.
Paper Title Page
TUP2WD04 Preliminary Design of HEPS Storge Ring Vacuum Chambers and Components 52
 
  • P. He, B. Deng, D.Z. Guo, Q. Li, B.Q. Liu, Y. Ma, Y.C. Yang, L. Zhang
    IHEP, Beijing, People's Republic of China
  • X.J. Wang
    Institute of High Energy Physics (IHEP), People's Republic of China
 
  In the design process of HEPS vacuum system, we meet the following limitations. Vacuum chamber must fit inside multipole magnet bore diameter of 25mm (without touching). Water channels and x-ray extraction ports must pass through a 11mm vertical pole gap. Provide an average pressure of 1nTorr during operations with 200mA beam current. Control thermal drift of BPM to ~μm and vibration amplitude ~nm level. Minimize impedance effects. This paper introduces the design of various vacuum chambers, including material selection, mechanical simulation analysis, welding test and so on.  
slides icon Slides TUP2WD04 [4.062 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FLS2018-TUP2WD04  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)