WEPPH033 | Stabilization of a Klystron Voltage at 100 PPM Level for PAL XFEL | 424 |
|
||
The PAL XFEL needs a stable electron beam. The stable charging of PFN (pulse forming network) of a klystron-modulator is essential to provide the stable acceleration field for an electron beam. For PAL XFEL, stabilization of klystron voltage pulses at 100 PPM level is required. Short-term stability is determined by a minimum resolution of a charging system. Long-term stability is determined by a thermal stability due to the temperature drift. This paper shows details of hardware R&D and test results to achieve the target stability. |