Lehmann, W.-D.

Paper Title Page
THPP034 Progress of the Rossendorf SRF Gun Project 534
 
  • J. Teichert, A. Arnold, H. Buettig, D. Janssen, U. Lehnert, P. Michel, K. Moeller, P. Murcek, Ch. Schneider, R. Schurig, F. Staufenbiel, R. Xiang
    FZR, Dresden
  • T.  Kamps, D. Lipka, F. Marhauser
    BESSY GmbH, Berlin
  • W.-D. Lehmann
    IfE, Dresden
  • J. Stephan
    IKST, Drsden
  • V. Volkov
    BINP SB RAS, Novosibirsk
  • I. Will
    MBI, Berlin
 
 

A superconducting rf photo electron injector (SRF gun) is under development at the Forschungszentrum Rossendorf. The project aims at several issues: improvement of the beam quality for the ELBE superconducting electron linac, demonstration of feasibility of this gun type, investigation of critical components, and parameter studies for future application (BESSY-FEL, 4GLS). In 2005, a substantial progress has been made. The two 3.5-cell niobium cavities for the gun have been delivered from the company ACCEL. The main parts for gun cryostat like vacuum vessel, cryogenic and magnetic shields are ready. Test benches for the cathode cooling system and the cavity tuner are being assembled. The photo cathode preparation lab has been arranged, and the diagnostic beam line has been designed (see T. Kamps et al., this conference). After delivering the gun cavities, their rf properties are being measured at room temperature and the warm tuning is being carried out. The set-up for this treatment and measurement as well as the results will be presented.