Author Index: A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z

Floettmann, K.

Paper Title Page
THPP030 Commissioning of TTF2 Bunch Compressors for Generation of 20 Femtosecond SASE Source 518
 
  • Y. Kim, K. Floettmann, S. Schreiber
    DESY, Hamburg
  • D. Son
    CHEP, Daegu
 
 

Funding: for the TTF2 VUV-FEL Team

By the help of nonlinearity in the longitudinal phase space, the VUV-FEL at the TESLA Test Facility phase 2 (TTF2) is under operating in the femtosecond (fs) FEL mode which generates coherent and ultra-bright SASE source with photon pulse duration time of around 20 fs (FWHM) and wavelength of around 32 nm. For the fs FEL mode operation, bunch length of electron beams should be compressed by two bunch compressors to have a leading spike in the longitudinal beam density distribution or peak current. The required peak current at the spike is higher than about 1.0 kA, and the spike length is shorter than around 200 fs (FWHM). In this paper, we describe our commissioning experiences to optimize two TTF2 bunch compressors for the fs FEL mode operation.

 
   
THPP037 First Experimental Demonstration of Ferrario's Matching Principle in TTF2 Booster Linac
 
  • Y. Kim, K. Floettmann, S. Schreiber
    DESY, Hamburg
 
 

Funding: for the TTF2 VUV-FEL Team

Generally, due to the space chare force, projected transverse emittance is increased at the region between gun and booster linac. However the emittance can be continuously damped in the booster linac by the so-called Ferrario's matching principle. Even though our longitudinal laser profile is not flat top shape during TTF2 commissioning, we could get a good emittance after booster linac (ACC1). For 1.0 nC and 90% beam intensity, our normalized projected transverse rms emittance was about 1.1 mm.mrad, and it was about 1.8 mm.mrad for 100% beam intensity. In this paper, we will compare our measured results with simulation ones, and we will show our first experimental demonstration of Ferrario's matching principle with Gaussian longitudinal laser beam profile.

 
   
THPP043 Status and First Results from the Upgraded PITZ Facility 564
 
  • A. Oppelt, K. Abrahamyan, G. Asova, J.W. Baehr, G. Dimitrov, U. Gensch, H.-J. Grabosch, J.H. Han, S. Khodyachykh, G. Klemz, M. Krasilnikov, S. Liu, V. Miltchev, B. Petrosyan, S. Riemann, L. Staykov, F. Stephan
    DESY Zeuthen, Zeuthen
  • W. Ackermann, W.F.O. Muller, S. Schnepp, T. Weiland
    TEMF, Darmstadt
  • D. Alesini, M. Boscolo, G. Di Pirro, M. Ferrario, D. Filippetto, L. Palumbo, C. Vicario
    INFN/LNF, Frascati (Roma)
  • V. Boccone
    Humboldt Universität zu Berlin, Berlin
  • L. Catani, E. Chiadroni, A. Cianchi
    INFN-Roma II, Roma
  • K. Floettmann, S. Schreiber
    DESY, Hamburg
  • T. Garvey
    LAL, Orsay
  • M.V. Hartrott, E. Jaeschke, D. Kraemer, D. Lipka, F. Marhauser, R. Richter
    BESSY GmbH, Berlin
  • P. Michelato, L. Monaco, C. Pagani, D. Sertore
    INFN/LASA, Segrate (MI)
  • V.V. Paramonov
    RAS/INR, Moscow
  • N. Pavel
    Humboldt University Berlin, Institut für Physik, Berlin
  • J.R. Roensch, J. Rossbach
    Uni HH, Hamburg
  • W. Sandner, I. Will
    MBI, Berlin
  • I. Tsakov
    INRNE, Sofia
 
 

Funding: This work has been partly supported by the European Community, contract numbers RII3-CT-2004-506008 and 011935, and by the 'Impuls- und Vernetzungsfonds" of the Helmholtz Association, contract number VH-FZ-05.

Since December 2004, the photo injector test facility at DESY in Zeuthen (PITZ) has been upgraded. A normal conducting copper booster cavity has been installed and the diagnostics beamline has been strongly modified. An extended water cooling system has been installed and was successfully taken into operation. Actually, the new diagnostics elements are being commissioned. After the installation of the new 10 MW klystron in June/July, the gun can be conditioned towards higher average power, and the whole beamline including the booster will be taken into operation. First results from the commissioning phase including gun and booster conditioning are reported.