Author: Girardot, P.
Paper Title Page
WEPP02 Commissioning of the High Intensity Proton Injector of the Facility for Anti Proton and Ion Research at CEA-Saclay 86
 
  • O. Tuske, N. Chauvin, O. Delferrière, Y. Gauthier, P. Girardot, N. Misiara, Y. Sauce, F. Senée, C. Simon
    CEA/IRFU, Gif-sur-Yvette, France
  • F. Ameil, R. Berezov, J. Fils, R. Hollinger
    GSI, Darmstadt, Germany
  • T.V. Vacher
    CEA/DSM/IRFU, France
 
  The Facility for Antiproton and Ion Research (FAIR) located at GSI (Darmstadt) in Germany addresses several fields of physics research within a single installation. One of the contribution of Irfu/SACM at CEA-Saclay to the FAIR linear proton accelerator concerns the development and construction of the ion source and the low energy line. The 2.45 GHz microwave ion source will deliver a 100 mA H+ beam pulsed at 4 Hz with an energy of 95 keV. A low energy beam transport (LEBT) line based on a dual solenoids focusing scheme allows the injection of the proton beam into the radio frequency quadrupole (RFQ) within an acceptance of 0.3π mm.mrad (norm., rms). An electrostatic chopper system located between the second solenoid and the RFQ is used to cut the beam macro pulse from the source to inject 36 μs long beam pulses into the RFQ. This article reports the finalization of the installation of the injector with the detail of dedicated diagnostics, the first beam measurements and gives a planning of the different commissioning phases  