Author: Caliri, C.
Paper Title Page
MODO01 Structural Information on the ECR Plasma by X-ray Imaging 30
 
  • R. Rácz, S. Biri
    ATOMKI, Debrecen, Hungary
  • C. Caliri, G. Castro, S. Gammino, D. Mascali, L. Neri, F.P. Romano
    INFN/LNS, Catania, Italy
  • J. Pálinkás
    DU, Debrecen, Hungary
  • F.P. Romano
    IBAM-CNR, Catania, Italy
 
  Precise knowledge on the density distribution of the Electron Cyclotron Resonance Ion Source plasma is needed by several reasons: i) in order to possibly improve the quality parameters of the extracted ion beam (emittance, brightness) strongly linked to the plasma structure, ii) to correctly investigate the recently observed plasma instabilities and/or the implementation of alternative heating methods (e.g. modal conversion) iii) in order to improve the general microwave-to-plasma coupling efficiency, in view of a microwave-absorption oriented design of future ECRIS. The non-destructive spectroscopic diagnostic methods give information always corresponding to an integration over the whole plasma volume. X-ray imaging by pin-hole camera can partly overcome this limitation. We performed volumetric and space resolved X-ray measurements at the ATOMKI ECRIS operated at lower frequencies than usual. The experimental setup in detail and the methods how the working parameters were selected will be shown. The integrated and photon-counting analyses of the collected plasma images show a strong effect of the frequency and magnetic field on the plasma structure and local energy content.  
slides icon Slides MODO01 [10.710 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-ECRIS2016-MODO01  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)