A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   R   S   T   U   V   W   Y   Z  

Ray, P. K.

Paper Title Page
TUCO-D03 Study of the Dependence of ECR Ion Current on Periodic Plasma Disturbance 169
 
  • Dr. G. S. Taki, R. K. Bhandari, D. K. Chakraborty, P. R. Sarma
    DAE/VECC, Calcutta
  • A. G. Drentje
    KVI, Groningen
  • T. Nakagawa
    RIKEN Nishina Center, Wako, Saitama
  • P. K. Ray
    Bengal Engineering and Science University, Howrah
 
  In a recent work we observed the existence of periodic current bursts from an ECR ion source when a biased disc is used for enhancing the extracted beam current. It was concluded that the current per burst in the source remains essentially constant. When the disc bias voltage is increased, the burst frequency increases, and so does the total current. Further it was seen that the current undergoes a jump at a fixed bias potential. The current jump has been found to be proportional to the charge state. The burst frequency also shows a correlated jump. However, in the case of protons a different trend is observed. As the bias potential is increased, at a particular potential value the current suddenly decreases. In this work we have studied the periodic bursts in the proton current in order to understand the difference in the behaviour of current jump in protons and heavy ions.