A   B   C   D   E   F   G   H   J   K   L   M   N   O   P   R   S   T   U   V   W   Z    

Weinrich, U.

Paper Title Page
IT03 Beam Loss Monitors at the ESRF 3
 
  • B. Joly, U. Weinrich, G.A. Naylor
    ESRF, The European Synchrotron Radiation Facility, Grenoble, France
 
  The European Synchrotron radiation facility is a third generation x-ray source providing x-rays on a continuous basis. As a facility available to external users, the monitoring of radiation caused by the loss of high-energy stored beam is of great concern. A network of beam loss monitors has been installed inside the storage ring tunnel so as to detect and localize the slow loss of electrons during a beam decay. This diagnostic tool allows optimization of beam parameters and physical aperture limits as well as giving useful information on the machine to allow the lifetime to be optimized and defects localized.