A   B   C   D   E   F   G   H   J   K   L   M   N   O   P   R   S   T   U   V   W   Z    

Stella, A.

Paper Title Page
PS07 Trajectory Measurements in the DAΦNE Transfer Lines 115
 
  • A. Stella, C. Milardi, M. Serio
    INFN-LNL, Laboratori Nazionali di Legnaro, Legnaro, Italy
 
  An improved beam position monitor system has been installed in the Transfer Lines (TL) connecting the DAΦNE Linac to the collider Main Rings through the Damping Ring, to monitor the beam trajectory and optimize the transmission efficiency. Signals from stripline type beam position monitors are stretched, sampled through Track & Hold circuits and digitized to 12 bits. The sampling stage is triggered, according to the timing of the desired beam, to measure the amplitude of the signals induced on a BPM. Hardware control, data collection and reconstruction of the beam position along the Transfer Lines are performed by the DAΦNE Control System on a VME standard local processor. Design issues, implementation and performance of the system are presented.