            It is well known that beam dispersion , along with the
            Twiss parameters and emittance, contributes to the beam
            spot size. So that, in general, anomalous dispersion is an
            undesirable event and must be minimized by careful tuning
            the machine. If not, when the spot size is used to infer
            beam emittances, as it is the case of the "quadrupole
            scan" method, basically employed at TTF, the unknown
            dispersion can lead to overestimated values for the emittance.
            This paper presents the first attempt to determine the
            dispersion function at several points of the TTF Linac and
            to separate its contribution to the local emittance measurement,
            performed by means of the OTR imaging technique.
             | 
              |