TUPB25 The Design and Implementation of the Machine Protection System for the FERMILAB Electron Cooling Facility 222
 
  • A. Warner, K. Carlson, L.R. Carmichael, J.L. Crisp, R.W. Goodwin, L.R. Prost, G.W. Saewert, A.V. Shemyakin
    Fermilab, Batavia
 
 

Abstract The Fermilab Recycler ring employs an electron cooler to store and cool 8.9-GeV antiprotons. The cooler is based on a 4.3MV, 0.1A, DC electrostatic accelerator (Pelletron) for which current losses have to remain low (~10-5) in order to operate reliably. The Machine Protection System (MPS) has been designed to interrupt the beam in a matter of 1-2 μs when losses higher than a safe limit are detected, either in the accelerator itself or in the beam lines. This paper highlights the various diagnostics, electronics and logic that the MPS relies upon to successfully ensure that no damage be sustained to the cooler or the Recycler ring.