TUPD36 Target Materials for a Low Energy Pepper-Pot Emittance Device 378
 
  • M.B. Ripert, A. Peters
    HIT, Heidelberg
 
 

The ion cancer therapy facility HIT in Heidelberg is producing ions (H, He, C and O) from two ECR sources at an energy of 8 keV/u with different beam currents from about 80 μA up to 1.2 mA. Typical sizes for the beam in the LEBT range from are 5 – 40 mm. Matching the always slightly changing output from the ECR sources to the first accelerating structure, an RFQ, demands a periodical monitoring of the beam emittance. For that, a special pepper-pot measurement device is under design, whose most important parts are a damage-resistant pepper-pot mask and a vacuum-suitable scintillator material. The investigation of the material lifetime is done in the first step by computing the maximum intensity the target volume can stand without any radiation damage, shock and heating. A list of feasible materials will be discussed and results from SRIM calculations for them will be shown. A set-up for necessary material tests with beam will be presented.