TUPB12 | Beam Test of the FAIR IPM Prototype in COSY | 191 |
|
||
The advanced ionization beam profile monitor is being developed at GSI for the future FAIR facility in collaboration with ITEP and FZ-Jülich. In January 2009 the IPM prototype was installed in COSY-Jülich. After successful hardware test the beam tests followed. The prototype was operated without magnetic field, thus only residual gas ions were detected. An arrangement consisting of an MCP stack, a phosphor screen, and a CCD camera was used to detect ions. We report the first profile measurements of the proton beam up to 2.8 GeV at COSY. |
||
WEOA04 | Beam Diagnostic Developments for FAIR | 424 |
|
||
The FAIR (Facility for Antiprotons and Ions Research) accelerator complex is currently designed and projected at GSI. The unique features of the central machine SIS100, like e.g. the acceleration of high intensity beams of 2.5·1013 protons and 5·1011 Uranium ions, the operation close to the space charge limit leading to a large tune spread and the extreme UHV conditions of the cryogenic system for fast ramped superconducting magnets, make challenging demands on the beam diagnostic components. This contribution describes the general concept of beam diagnostics for FAIR and reports on the present status of prototype studies. Exemplarily the achievements for a novel type of dc transformer, beam position monitors and the ionization profile monitor are discussed and first measurements with prototype setups are presented. |
||
|