MOPD31 Beam Diagnostics in the CNAO Injection Lines commissioning 119
 
  • G. Balbinot, E. Bressi, M. Caldara, A. Parravicini, M. Pullia, M. Spairani
    CNAO Foundation, Milan
  • C. Biscari
    INFN/LNF, Frascati (Roma)
  • J. Bosser
    CERN, Geneva
 
 

The CNAO, the first Italian center for deep hadrontherapy, is presently in its final step of installation. It will deliver treatments with active scanning both with Proton and Carbon ion beams. Commissioning of the low energy injection lines has been successfully concluded in January 2009. CNAO beams are generated by two ECR sources which are both able to produce both particle species. The beam energy in the Low Energy Beam Transfer (LEBT) line is 8 keV/u. A compact and versatile tank containing a complete set of diagnostic tools has been intensively used for the line commissioning: in a length of 390mm it houses two wire scanners, for vertical and horizontal beam transverse profile, a Faraday Cup, for current measurement, and two vertical and horizontal plates for beam halo suppression , emittance measurements, beam collimation and particles selection. Using one tank devices, phase space distribution reconstruction can be quickly performed as well as synchronous profiles and intensity measurements. Commissioning results and measurements are presented.