A   B   C   D   E   F   G   H   I   K   L   M   O   P   Q   R   S   T   U   V  

scattering

Paper Title Other Keywords Page
TUPC05 Screen studies at PITZ emittance, electron, simulation, diagnostics 153
 
  • R. Spesyvtsev, J. W. Bähr, S. Khodyachykh, L. Staykov
    DESY Zeuthen, Zeuthen
  The Photo Injector Test facility at DESY in Zeuthen (PITZ) has been built to test and to optimize electron sources that fulfill the requirements of SASE FEL's such as FLASH and XFEL. Basic properties of the electron beam such as mean momentum, momentum spread, transverse emittance etc. are determined using measurement of the beam size on YAG or OTR screens. Detailed knowledge of the uncertainties and systematic errors associated with these measurements are important to understand the underlying beam physics. The screen stations consist of a screen set-up, an optical transmission line to a CCD camera, and the video data acquisition system. In this paper we make a detailed description of the screen based beam size measurement systems that we use at PITZ and discuss the systematic errors of uncertainties associated with each single element of a system.  
 
WEPB22 Touschek Lifetime Measurement with a Spurious Bunch in UVSOR-II Electron Storage Ring electron, single-bunch, vacuum, storage-ring 280
 
  • A. Mochihashi, M. Katoh, M. Shimada
    UVSOR, Okazaki
  • Y. Hori
    KEK, Ibaraki
  • M. Hosaka, Y. Takashima
    Nagoya University, Nagoya
  We have developed a method to measure the Touschek beam lifetime of an electron storage ring using spurious bunches in single-bunch operation by measuring change in the single-bunch impurity over time. To measure a spurious bunch and the main bunch simultaneously, we use a photon counting method with sufficient dynamic range and response time. We demonstrated the method by measuring the Touschek beam lifetime in the UVSOR-II electron storage ring. We find that the Touschek beam lifetime dominates the total beam lifetime in UVSOR-II in usual vacuum condition. The Touschek beam lifetime measurement in multibunch operation with the method will be discussed in the presentation.

A. Mochihashi, M. Katoh, M. Hosaka, Y. Takashima, Y. Hori, NIM-A 572 (2007) 1033-1041.

 
 
WEPC14 Segmented Beam Dump for Time Resolved Spectrometry on a High Current Electron Beam electron, radiation, simulation, linac 340
 
  • T. Lefèvre, H.-H. Braun, E. Bravin, C. Dutriat, C. P. Welsch
    CERN, Geneva
  In the CLIC Test Facility 3, the strong coupling between the beam and the accelerating cavities induces transient effects such that the head of the pulse is accelerated twice as much as the rest of the pulse. Three spectrometer lines are installed along the linac with the aim of measuring energy spread versus time with a 20ns resolution. The major difficulty is due to the high power carried by the beam which imposes extreme constraints of thermal and radiation resistances for the detector. This paper presents the design and the performances of a simple and easy-to-maintain device, called ‘segmented dump’. In this device, the particles are stopped inside metallic plates and the deposited charge is measured in the same way as in faraday cups. Simulations were carried out with the Monte Carlo code ‘FLUKA’ in order to evaluate the problems coming from the energy deposition and find ways to prevent or reduce them. The detector resolution has been optimized by choosing the adequate material and thickness for the plates. The overall layout of the monitor is described with a special emphasis on its mechanical assembly. Finally, limitations arising at high beam energies are discussed.