- D. A. Liakin, S. V. Barabin, A. Y. Orlov
ITEP, Moscow
- P. Forck, T. Giacomini
GSI, Darmstadt
|
A sample of SiPM (silicon photomultiplier) has been tested as an elementary light detector for accelerated beam fast profile evolution observation by using it in residual gas ionization profile monitors. A noise, sensitivity, dynamic range and timing parameters tests of SiPM were performed. A procedure of the data acquisition and following signal reconstruction is discussed. A special attention has been paid to the fine time resolution counting mode with single photon detection. A dedicated signal normalizing and time-to-digit converter design was prototyped and tested. In addition some different modes of operation and optical schemes are discussed in this paper. It is shown that fast optical detectors like SiPMs also could be used for high performance profile measurements with spatial resolution compatible with CCD sensors.
|
|
|
|