PM05 | Optical Transmission Line For Streak Camera Measurements at Pitz | 98 |
|
||
The photoinjector injector test facility at DESY Zeuthen (PITZ) [1]
produces electrons with a momentum of about 4 MeV/c. It is the aim to
measure the temporal characteristics of the electron bunch train and
single bunches with high accuracy of the order of 1 ps and less. Several
types of streak cameras will be used in combination with different
radiators which transform particle energy in light. The problem to be
solved is the light transport over a distance of about 27 m. Basic demands
to the optical system and design principles will be explained. The
optical and technical solutions will be presented. The strategy of
adjustment and commissioning of the optical system will be described. The
system contains switchable optics to use different radiators (OTR,
Cherenkov radiators). Diagnostic tools are foreseen at different
positions along the optical axis. The results of different measurements
in the lab and using the original system will be presented. The problems
on the minimalization of the time dipersion in the system will be
discussed.
[1] F.Stephan, et al., Photo injector test facility under construction at DESY Zeuthen, FEL 2000, Durham |