The transfer line from the CERN proton synchrotron
(PS) to the super proton synchrotron (SPS) requires a new
beam position measurement system in view of the LHC.
In this line, the single passage of various beam types
(up to 7), induces signals with a global signal dynamics of
more than 100 dB and with a wide frequency spectral
distribution.
Logarithmic amplifiers, have been chosen as technical
solution for the challenges described above.
The paper describes the details of the adopted solutions
to make beam position measurements, with a resolution
down to few 10-4 of the full pickup aperture over more
than 50 dB of the total signal dynamics.
The reported performances has been measured on the
series production cards, already installed into the machine
and on one pickup in the transfer line.
|
|