PM19 The Dynamic Tracking Acquisition System for DAΦNE e+/e--Collider 213
 
  • A. Drago, A. Stella, M. Serio
    INFN-LNF, Laboratori Nazionali di Frascati, Frascati, Italy
 
  The goal of this paper is to describe the dynamic tracking acquisition system implemented for the DAΦNE e+/e--collider at LNF/INFN. We have been using the system since last year and it has been possible to collect useful information to tune-up the machine. A four-button BPM is used to obtain the sum and difference signals in both the transverse planes. The signals are acquired and recorded by a LeCroy LC574A oscilloscope with the capability to sample the input waveforms using a beam synchronous external clock generated by the DaFne Timing System. The start of acquisition is synchronised to a horizontal kick given by an injection kicker. After capturing up to 5000 consecutive turns, data are sent through a GPIB interface to a PC, for processing, presentation and storage. A calibration routine permits to convert voltage data to millimeters values. The acquisition and control program first shows the decay time in number of turns. Then it draws a trajectory in the phase space (position and speed) in both the transverse planes. To do this the software builds a data vector relative to a second "virtual" monitor advanced by 90 degrees. This is done by two alternative ways: applying the Hilbert transform or using the transport matrix method. Examples of data acquired during the collider tune-up are shown.