Schlott, V.

Paper Title Page
CT03 Performance of the Digital BPM System for the Swiss Light Source 69
 
  • V. Schlott, M. Dach, M. Dehler, R. Kramert, P. Pollet, T. Schilcher
    PSI, Paul Scherrer Institut, Villigen, Switzerland
  • M. Ferianis, R. DeMonte
    ELETTRA, Sincrotrone Trieste, Trieste, Italy
  • A. Košiček, R. Uršič
    I-Tech, Instrumentation Technologies, Solkan, Slovenia
 
  The accelerator complex of the Swiss Light Source (SLS) is presently under commissioning at the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The newly developed digital beam position monitor (DBPM) system has been successfully used to determine beam positions in the pre-injector LINAC, the transfer lines, the booster synchrotron and the storage ring. Instant and free selection of operation modes through the EPICS-based SLS control system allows to choose between single turn, turn-by-turn and closed orbit measurements. The operational experience and performance of the DBPM system is presented, based on measurements, taken during SLS commissioning. A monitoring system (POMS), which measures the horizontal and vertical mechanical positions of each BPM block in reference to the adjacent quadrupole magnets has been installed and first results, indicating transverse movements of the BPM blocks as a function of current in the storage ring will be presented.  
PS13 A Zone Plate Based Beam Monitor for the Swiss Light Source 133
 
  • C. David
    PSI-LMN, Laboratory for Micro- and Nanotechnology, Paul Scherrer Institute, Villigen, Switzerland
  • V. Schlott, A. Jaggi
    PSI-SLS, Swiss Light Source, Paul Scherrer Institute, Villigen, Switzerland
 
  At the Swiss Light Source, a source imaging set-up is planned on a dedicated dipole magnet beam-line. A transmission Fresnel Zone Plate will be used to generate a demagnified image of the source at a photon energy in the 1.8 keV range. The image will be acquired by scanning a pinhole in the image plane. A diffraction limited spatial resolution of approximately 2 microns can be anticipated. The concept has the advantage of having no components operated in reflection, and no components inside the frontend.  
DS04 Calibration and Stability of Diagnostics Equipment
Session 4: Tuesday Morning (11:30--13:00 Hrs)
228
 
  • V. Schlott
    PSI, Paul Scherrer Institut, Villigen, Switzerland
 
  Calibration and Stability of Diagnostics Equipment Topics are divided in 3 categories:
  1. Beam Position Monitors (BPMs)
  2. Current Monitors
  3. Optical Monitors