A   B   C   D   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   V   W   X   Y   Z  

Prost, L. R.

Paper Title Page
MOA2I06 Electron Cooling Status and Characterization at Fermilab’s Recycler 49
 
  • L. R. Prost, A. V. Burov, K. Carlson, A. V. Shemyakin, M. Sutherland, A. Warner
    Fermilab, Batavia, Illinois
 
  Funding: Operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the United States Department of Energy

FNAL’s electron cooler (4.3 MV, 0.1 A DC) has been integrated to the collider operation for almost two years, improving the storage and cooling capability of the Recycler ring (8 GeV antiprotons). In parallel, efforts are carried out to characterize the cooler and its cooling performance. This paper discusses various aspects of the cooler performance and operational functionality: high voltage stability of the accelerator (Pelletron), quality of the electron beam generated, operational procedures (off-axis cooling, electron beam energy measurements and calibration) and cooling properties (in the longitudinal and transverse directions). In particular, we show measurements of the friction force and cooling rates, which we compare to a non-magnetized model and conclude that the effective electron beam radius is smaller than expected.

 
slides icon Slides  
THAP08 Electron Cooling in the Recycler Cooler 175
 
  • A. V. Shemyakin, L. R. Prost
    Fermilab, Batavia, Illinois
  • A. V. Fedotov
    BNL, Upton, Long Island, New York
  • A. O. Sidorin
    JINR, Dubna, Moscow Region
 
  Funding: FNAL is operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the United States Department of Energy.

A 0.1-0.5 A, 4.3 MeV DC electron beam provides cooling of 8 GeV antiprotons in Fermilab's Recycler storage ring. Properties of electron cooling have been characterized in measurements of the drag force, cooling rates, and equilibrium distributions. The paper will report experimental results and compare them with modeling by BETACOOL code.

 
THAP09 Beam-based Field Alignment of the Cooling Solenoids for Fermilab’s Electron Cooler 179
 
  • L. R. Prost, A. V. Shemyakin
    Fermilab, Batavia, Illinois
 
  Funding: Operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the United States Department of Energy

The cooling section of FNAL’s electron cooler is composed of ten (10) 2 m-long, 105 G solenoids. When FNAL’s electron cooler (4.3 MeV, 0.1 A DC) was first install at the Recycler ring, the magnetic field of the cooling solenoid was carefully measured and compensated to attain the field quality necessary for effective cooling [V. Tupikov et al. COOL’05]. However, the tunnel ground motion deteriorates the field quality perceived by the beam over time. We have developed a technique which uses the cooling strength as an indication of the relative field quality and allowing us to re-align the longitudinal magnetic field in the successive solenoids of the cooling section assuming that the transverse component of the field in each solenoid has not varied.