One of the most critical elements for the protection of CERNs Large Hadron Collider (LHC) is its beam loss monitoring (BLM) system. It aims to prevent the super conducting magnets from quenching and to protect the machine components from damages, as a result of critical beam losses. The contribution will discuss the commissioning procedures of the BLM system and the envisaged operational scenarios. About 4000 monitors will be installed around the ring. The specification for the BLM system includes a factor of 2 absolute precisions on the prediction of the quench levels, a wide range of integration times (100 us to 100 s) and a fast (one turn) trigger generation. When the loss rate exceeds a pre-defined threshold value, a beam abort is requested. Magnet quench and damage levels vary as a function of beam energy and loss duration. Consequently, the beam abort threshold values vary accordingly. By measuring the loss pattern, the BLM system helps to identify the loss mechanism. Furthermore, it will be an important tool for commissioning, machine setup and studies. Special monitors will be used for the setup and control of the collimators.
|
|