THPMA088 Bremsstrahlung Converter For High Power EB Radiation Processing Facility 767
 
  • V. C. Petwal, S. C. Bapna, S. Kotaiah, R. S. Sandha
    RRCAT, Indore (M. P.)
  • K. V. Subbaiah
    Safety Research Institute, Indira Gandhi Center for Atomic Research, Tamilnadu
 
  A radiation processing facility based on 10 kW Linac is being set up at RRCAT for irradiation of food products and sterilization of medical items. The facility is planned to operate in electron (10 MeV) and X-ray (5 & 7.5 MeV)mode. The required X-rays will be generated by bombarding an optimised target with 5 or 7.5 MeV electron beam. Monte Carlo simulation with MCNP has been performed to optimise the design of the targets for maximizing the X-ray output. The composite target is made of Ta, water & SS. Characteristics of the emerging X-ray field e.g. photon energy spectrum, angular distribution, radial dose and depth dose distribution in unit density material have been simulated & compared for 5 & 7.5 MeV. Our simulation results show that for optimised design, the fraction of the energy transmitted at 5 & 7.5 MeV is 9.3% & 14.2 % respectively, which is useful for radiation processing. The most probable energy of the photons is 0.3 MeV for both 5 and 7.5 MeV electrons and the average energy is 0.84 MeV & 1.24 MeV respectively. Large fraction of electron beam power is dissipated as heat in the targets. Necessary data has been generated to carry out thermal design.