THPMA081 Precise Positioning of Magnetic Field Centers of Quadrupole Magnets on the Girder 749
 
  • L. Tsai, T.-C. Fan, S. Y. Perng, D.-J. Wang
    NSRRC, Hsinchu
 
  Conventional alignment of quadrupole magnet on the girder is mainly based on the measurement of theodolite and fiducial. Most of the measurement errors come from human-eye resolution and fiducial precision. The resultant cumulative error could be in the order of 50~100μm. In this paper, pulsed wire method is proposed to align group of quadrupole magnets concentrically on one girder to precision about 10μm. In order to increase the alignment accuracy, sag problem in tension wire is replaced by a short wire with laser PSD system. Descriptions of the setup and test results are presented.

quadrupole magnet alignmentpsd